Comparison of solid-phase extraction sorbents for cleanup in pesticide residue analysis of fresh fruits and vegetables

2002 ◽  
Vol 25 (14) ◽  
pp. 883-890 ◽  
Author(s):  
Frank J. Schenck ◽  
Steven J. Lehotay ◽  
Victor Vega
1991 ◽  
Vol 16 (2) ◽  
pp. 247-255 ◽  
Author(s):  
Yoshitsugu ODANAKA ◽  
Naomi TOMIYAMA ◽  
Yukiko KOMA ◽  
Osami MATANO ◽  
Shinko GOTO

2008 ◽  
Vol 91 (3) ◽  
pp. 630-636 ◽  
Author(s):  
Mijeong Lee Jeong ◽  
Michael Zahn ◽  
Thao Trinh ◽  
Fay A Brooke ◽  
Wenwen Ma

Abstract A sample cleanup procedure has been developed to remove coextractives that interfere with pesticide residue analysis of a dietary ingredient (Product B), an extract consisting of Scutellaria baicalensis and Acacia catechu. Samples were extracted using 1 acetic acid in acetonitrile, followed by solid-phase extraction and analysis by capillary gas chromatography with mass spectrometry in the selective-ion monitoring mode. Neutral alumina (alumina N) was found to be the most effective sorbent to remove coextractives from Product B; other materials that were tested but failed to remove interference were graphitized carbon black/primary-secondary amine (PSA), octadecylsilane (C18), Florisil, Oasis MCX, and strong anion exchange-PSA. The method was specifically developed for Product B, which was spiked with 41 organochlorine and organophosphorus pesticides, and resulted in the recovery of 80 to 120 at U.S. Pharmacopeia limits (0.06 to 4 g/g) for the majority of the pesticides.


2018 ◽  
Vol 10 (7) ◽  
pp. 757-766 ◽  
Author(s):  
Pengyue Zhao ◽  
Pedro J. J. Alvarez ◽  
Xuesheng Li ◽  
Canping Pan

A dispersive SPE with PSA and MWCNTs as sorbent material was developed for pesticide residue analysis in berry samples.


2008 ◽  
Vol 91 (6) ◽  
pp. 1459-1466 ◽  
Author(s):  
Ji-Ye Hu ◽  
Yu-Chao Zhang ◽  
Hai Yan

Abstract A method for high-performance liquid chromatographic (HPLC) determination of flumorph residues in cucumber, tomato, soil, and natural water was developed and validated. Primary secondary amine or octadecylsilyl (C18) solid-phase extraction cartridges were used for sample preparation. Reversed-phase HPLC with UV detection was used for separation and quantification of the pesticide. The combined cleanup and chromatographic method steps were sensitive and reliable for simultaneous determination of residues of the 2 isomers of flumorph in the studied samples. This method is characterized by recovery >97.9, coefficient of variation <6.2, and limit of quantification of 0.01 mg/kg, in agreement with directives for method validation in residue analysis. Flumorph residues in the samples were further confirmed by HPLC/mass spectrometry. The proposed method is fast, easy to perform, and could be used for monitoring of pesticide residues.


1991 ◽  
Vol 74 (6) ◽  
pp. 991-998 ◽  
Author(s):  
Keh-Chuh Ting ◽  
Peng Kho

Abstract This research describes the results of a gas chromatography/microwave induced plasma/atomic emission detection (GC/MIP/AED) method performed on a Hewlett-Packard 5921A system for pesticide residue analysis in fruits and vegetables. Atotal of 6 experiments were conducted: (1) sensitivity and linearity studies for elements S, P, CI, and N by analyzing dursban; (2) a study of instrument response to CI concentration in pesticide molecules; (3) organochlorinated pesticide recoveries; (4) organophosphate pesticide recoveries; (5) carbamate pesticide recoveries; and (6) investigation of metallic pesticides with pllctran and vendex as standards. The rank according to sensitivity and linearity was found to be as follows: S-181>P-178>CI-479>N-174. Instrument response to the concentration of chlorine atoms in the pesticide molecule was linear, with a correlation coefficient of 0.89. Recoveries of organochlorinated pesticides were 91.7-109.3%, with the exception of citrus, whose recovery was affected by coeluting Interferences. Organophosphate recoveries were 73.2% or higher, except for the cygon oxygen analog, which degraded in the GC system under all circumstances. Carbamate recoveries were inconsistent quantitatively; however, the information generated from elements N and S were useful for qualitative confirmation of other methods, such as LC postcolumn derivatization analysis. Overall, the GC/MIP/AED method is powerful for qualitative confirmation in pesticide residue analysis. The instrument’s capability of acquiring multi-elements (CI and P) selectively and accurately is an alternative method for organochlorinated and organophosphate pesticide residue analyses. In addition, the GC/MIP/AED system is easy to use, simple to maintain, and its chromatograms can be interpreted by any chromatography analyst without much prior training.


Sign in / Sign up

Export Citation Format

Share Document